Power Quality Analyzer Class A Energy Analyzer Harmonic Tester
Ask sales reps for details.
Part No: PQAN7620
Features:
More accurate up to 0.1% on Vrms(voltage), Frequency: 0.01Hz
Meet standard: IEC61000-4-30 Class S
Phase: -180~180
Lart 5.6 inch TFT LCD 640*480 resolution
With USB and lan interface
Safety standard: IEC61010-1 ,Safety Degree: 600V CAT IV 1000V CAT III
Specification:
| Selection Table | |
| Model | PQAN7610 |
| Standard compliance | IEC61000-4-30 Class A |
| Volt Amp Hz | ● |
| Dips and swell | ● |
| Harmonics | ● 100th Max. |
| Power and energy | ● |
| Unbalance | ● |
| Monitor | ● |
| Inrush | ● |
| Flicker | ● |
| Transients | ● |
| 400Hz | ● |
| Wave Recording | ● |
| Sample rate | 163.84kS/s (50/60Hz) |
| TF Card | 32GB |
| Battery | Lithium ion, 7.4V 5200mAh |
| GPS/Beidou time synchronization | ● (option) |
| WIFI | ● |
| Input Characteristics | |
| Number of inputs | 4 (3 phase + neutral) DC coupling |
| Voltage Inputs | |
| Max. input voltage | 1000Vrms |
| Max. peak measurement voltage | 6kV |
| Input Impedance | 4MΩ |
| Current Input | |
| Type | Clamp or current transformer with mV output |
| Input Range | depends on supplied current clamp |
| Input Impedance | 50kΩ 100kΩ (SA2200) |
| Sampling System | |
| Resolution | 8 channels 16 bits AD |
| Sampling Rate | 163.84kS/s (50/60Hz), 8 channels sample
synchronously (SA2200) |
| Measurement | |||
| Measurement Range | Resolution | Accuracy | |
| Voltage/Current/Frequency | |||
| Vrms(AC+DC) | 1 ~ 1000Vrms | 0.01Vrms | ±0.1% of nominal
voltage |
| Vpk | 1 ~ 1400Vpk | 0.01Vpk | ±0.5% of nominal
voltage |
| V(Crest Factor) | 1.0 ~ >2.8 | 0.01 | ±5% |
| Arms(AC) 10mV/A 1mV/A 65mV/1000A (AC) |
|||
| 0~150A | 0.01A | ±0.1%±0.1A | |
| 1~2000A | 0.01A | ±0.1%±0.1A | |
| 10~6000A | 0.01A | ±1%±2A | |
| A(Crest Factor) | 1 ~ 10 | 0.01 | ±5% |
| Frequency | 42.5~57.5(50Hz nominal) | 0.01Hz | ±0.01Hz |
| 51~69(60Hz nominal) | 0.01Hz | ±0.01Hz | |
| 320~480(400Hz nominal) | 0.01Hz | ±0.01Hz | |
| Dips & Swells | |||
| Vrms1/2 | 0 ~ 200% of nominal voltage | 0.01Vrms | ±0.2% |
| Arms1/2 | depends on current clamps | 0.01A | ±1% |
| Harmonic (IEC61000-4-7) | |||
| Harmonic Number | 1 ~ 100(50/60Hz) (IEC61000-4-7) 1~12(400Hz) | ||
| Harmonic Voltage %f | 0.0 ~ 100.0% | 0.01% | ±0.1% ± nx0.1% |
| Harmonic Current %f | 0.0 ~ 100.0% | 0.01% | ±0.1% ± nx0.1% |
| THD | 0.0 ~ 100.0% | 0.01% | ±2.5% |
| Phase | -180° ~180 0° | 0.1° | ± nx0.1° |
| Power and Energy | |||
| P, S, Q1 | Max. 6000MW | 0.1kW | ±1%±10 digits |
| PF & cosФ | 0 ~ 1 | 0.01 | ±0.1% |
| kWh, kVAh, kvarh | depends on nominal voltage and current clamps | ±1%±10 digits | |
| Flicker (IEC61000-4-15) | |||
| Pst(10min)/Plt (2 hrs) | 0.00 ~ 20.00 | 0.01 | ±5% |
| Unbalance | |||
| Voltage | 0.0 ~ 20.0% | 0.1% | ±0.1% |
| Current | 0.0 ~ 20.0% | 0.1% | ±1% |
| Voltage Phase | -360° ~ 0° | 0.1° | ±0.1° |
| Current Phase | -360° ~ 0° | 0.1° | ±0.5° |
| Voltage Transient | |||
| Vpk | ±6000Vpk | 1V | ±15% |
| Vrms | 10 ~ 1000Vrms | 1V | ±2.5% |
| Min. Test Time | 6.5us | ||
| Inrush Current | |||
| Arms | depends on current clamps | 0.01 | ±1% ± 5digits |
| Inrush Duration | 1 ~ 32min selectable | 10ms | ±20ms |
| Logger | |||
| Recording | user-defined parameters for 4 phases at the same time | ||
| Memory | Data stored in TF card, 32GB | ||
| Duration Time | 2 hrs to 1 year, depends on the recording items and time interval | ||
| Interval | 1s to 60 minutes | ||
CT clamps: (Option)
A: Range: 5A, Output Voltage Ratio: 10mV/A Accuracy: 0.2%
Working Frequency: 45Hz~55Hz Clamps Radius: 8mm
Size: 158*43*24mm
B: Range: 50A, Output Voltage Ratio: 10mV/A Accuracy: 0.2%
Working Frequency: 50Hz~400Hz Clamps Radius: 8mm
Size: 171*46*27mm
C: Range: 100A, Output Voltage Ratio: 10mV/A Accuracy: 0.2%
Working Frequency: 50Hz~400Hz Clamps Radius: 13mm
Size: 174*52*27mm
D: Range: 1A~1000A, Output Voltage Ratio: 1mV/A Accuracy: 1%
Working Frequency: 40Hz~100Hz Clamps Radius: 52mm
Size: 111*216*45mm
E: Flex type Primary Current Rating: 3000A , Output Voltage Ratio: 65mV/1000A
Range: 15A~3000A Accuracy: 1%+position Error
Maximum Allowable imput: 100KA Phase Error: Less than 1%
Noise: less than 2mVrms(10Hz~10Khz) Frequency Characteristic: 10Hz~10KHz(-3db)
Weight: 130g Length: 200cm CT perimeter: 50cm Postion Error: 2%
F: Flex type Primary Current Rating: 5000A , Output Voltage Ratio: 50mV/1000A
Range: 20A~1000A Accuracy: 1%+position Error
Maximum Allowable imput: 100KA Phase Error: Less than 1%
Noise: less than 2mVrms(10Hz~10Khz) Frequency Characteristic: 10Hz~10KHz(-3db)
Weight: 130g Length: 200cm CT perimeter: 50cm Postion Error: 2%


| General | |
| Batteries Inside | Lithium ion, 7.4V 5200mAh |
| Characteristic | Dips and swell, Harmonic(IEC61000-4-30), Power and Energy |
Power Quality Analyzer Class A Energy Analyzer Harmonic Tester
- Product Code: PQAN-7620
- Availability: 2-3 Days
-
$3,328.00
Related Products
UT205E Digital Clamp Meter True RMS AC DC Current
UT205E Digital Clamp Meter True RMS AC DC Current ..
$49.99
UT220 2000A Auto Range Digital Clamp Meter Megohmmeter
UT220 2000A Auto Range Digital Clamp Meter Megohmmeter 750V Voltage Tester Full Icon Display Low Bat..
$99.66
100V ACV UT171A UT171B UT171C True RMS Digital Multimeter Eletronic Tester
100V ACV UT171A UT171B UT171C True RMS Digital Multimeter Eletronic TesterUT171 series are industria..
$165.00
UT521Digital Earth Grounding Resistance Tester Poor Contact Display
UT521 Digital Earth Grounding Resistance Tester Poor Contact Display Features &n..
$164.99
3 Phase Rotation Meter Phase Sequence Indicator With Alarm
3 Phase Rotation Meter Phase Sequence Indicator With Alarm Features: 1.One Unit with two funct..
$23.99
40mF Capacitance Meter Intelligent Digital Multimeter UT71C
40mF Capacitance Meter Intelligent Digital Multimeter UT71C UT71 series can quickly sol..
$216.99
8-120V Coulomb Counter 50A Battery Capacity Detector
120V Coulomb Counter 50A Battery Capacity Type A 0-75A Specification Voltage: 8~120V Current..
$39.99
UT523A Digital Earth Ground Resistance Voltage Soil Resistivity Tester With Alarm
UT523A Digital Earth Ground Resistance Voltage Soil Resistivity Tester With Alarm &..
$588.49
Tags: Power Quality Analyzer, Energy Analyzer, Harmonic Power Analyzer
Featured
DIN 862 Digital Caliper Extra Large Display Vernier Caliper Slide
DIN 862 Digital Caliper Extra Large Display Vernier Caliper Slide ISO17025 Not Including Th..
$28.99 $35.99
Steel Wire Rope Hoisting Cable Diameter Digital Caliper Sponge Thickness Vernier Caliper
Steel Wire Rope Hoisting Cable Diameter Digital Caliper With Large Measuring Jaw Sponge Th..
$77.99
Universal Bridge Cam Welding Gage
Universal Bridge Cam Welding Gage WGU-8M WG-218 is updated from ROK WG-208, These two ..
$18.99
Dual Range NCV test 35/6 Bit Digital Multimeter
Dual Range NCV test 35/6 Bit Digital Multimeter Features: 1. AC DC measureme..
$48.90
Latest
Underground Metal Detector High Sensitive Anti-Drop
Underground Metal Detector High Sensitive Anti-Drop Features: High Accuracy; IP 68 ..
$110.00
Metal Detector with Dial Expansion Length 30.7-42.5in
Metal Detector with Dial Expansion Length 30.7-42.5in A Metal Detector..
$48.99
LA 0-100mm Caliper Gauge 450mmDeep Throat
LA 0-100mm Caliper Gauge 450mmDeep Throat Range: 0-100mm Resolution: 0.1mm Throat: 450mm ..
$266.00
Underground Metal Detector For Non-ferrous Ferrous Metals
Underground Metal Detector For Non-ferrous Ferrous Metals Description: This underground ..
$39.99
High Accuracy Precision Balance 30kg 50kg Repeatability 0.5g
High Accuracy Precision Balance 30kg 50kg Repeatability 0.5g PRBA-3503-30 30KG PR..
$1,599.00
Lab Precision Balance Scale 1000g 2000g 3000g 4000g 5000g 6000g
Lab Precision Weighing Balance Scale 10mg PRBA-3502-1000 ..
$411.00
Lab Electronic Precision Balance 1mg Automatic Calibration
Lab Electronic Precision Balance 1mg Automatic Calibration PRBA-3501-100 A P..
$377.00
Analytical Balance Anti- Electromagnetic Interference Shell 0.1mg
Analytical Balance Anti- Electromagnetic Interference Shell 0.1mg Weight based on its dimension, ..
$388.00














-200x200.jpg)
-200x200.jpg)




-200x200.jpg)