Power Quality Analyzer Class A Energy Analyzer Harmonic Tester
Ask sales reps for details.
Part No: PQAN7620
Features:
More accurate up to 0.1% on Vrms(voltage), Frequency: 0.01Hz
Meet standard: IEC61000-4-30 Class S
Phase: -180~180
Lart 5.6 inch TFT LCD 640*480 resolution
With USB and lan interface
Safety standard: IEC61010-1 ,Safety Degree: 600V CAT IV 1000V CAT III
Specification:
Selection Table | |
Model | PQAN7610 |
Standard compliance | IEC61000-4-30 Class A |
Volt Amp Hz | ● |
Dips and swell | ● |
Harmonics | ● 100th Max. |
Power and energy | ● |
Unbalance | ● |
Monitor | ● |
Inrush | ● |
Flicker | ● |
Transients | ● |
400Hz | ● |
Wave Recording | ● |
Sample rate | 163.84kS/s (50/60Hz) |
TF Card | 32GB |
Battery | Lithium ion, 7.4V 5200mAh |
GPS/Beidou time synchronization | ● (option) |
WIFI | ● |
Input Characteristics | |
Number of inputs | 4 (3 phase + neutral) DC coupling |
Voltage Inputs | |
Max. input voltage | 1000Vrms |
Max. peak measurement voltage | 6kV |
Input Impedance | 4MΩ |
Current Input | |
Type | Clamp or current transformer with mV output |
Input Range | depends on supplied current clamp |
Input Impedance | 50kΩ 100kΩ (SA2200) |
Sampling System | |
Resolution | 8 channels 16 bits AD |
Sampling Rate | 163.84kS/s (50/60Hz), 8 channels sample
synchronously (SA2200) |
Measurement | |||
Measurement Range | Resolution | Accuracy | |
Voltage/Current/Frequency | |||
Vrms(AC+DC) | 1 ~ 1000Vrms | 0.01Vrms | ±0.1% of nominal
voltage |
Vpk | 1 ~ 1400Vpk | 0.01Vpk | ±0.5% of nominal
voltage |
V(Crest Factor) | 1.0 ~ >2.8 | 0.01 | ±5% |
Arms(AC) 10mV/A 1mV/A 65mV/1000A (AC) |
|||
0~150A | 0.01A | ±0.1%±0.1A | |
1~2000A | 0.01A | ±0.1%±0.1A | |
10~6000A | 0.01A | ±1%±2A | |
A(Crest Factor) | 1 ~ 10 | 0.01 | ±5% |
Frequency | 42.5~57.5(50Hz nominal) | 0.01Hz | ±0.01Hz |
51~69(60Hz nominal) | 0.01Hz | ±0.01Hz | |
320~480(400Hz nominal) | 0.01Hz | ±0.01Hz | |
Dips & Swells | |||
Vrms1/2 | 0 ~ 200% of nominal voltage | 0.01Vrms | ±0.2% |
Arms1/2 | depends on current clamps | 0.01A | ±1% |
Harmonic (IEC61000-4-7) | |||
Harmonic Number | 1 ~ 100(50/60Hz) (IEC61000-4-7) 1~12(400Hz) | ||
Harmonic Voltage %f | 0.0 ~ 100.0% | 0.01% | ±0.1% ± nx0.1% |
Harmonic Current %f | 0.0 ~ 100.0% | 0.01% | ±0.1% ± nx0.1% |
THD | 0.0 ~ 100.0% | 0.01% | ±2.5% |
Phase | -180° ~180 0° | 0.1° | ± nx0.1° |
Power and Energy | |||
P, S, Q1 | Max. 6000MW | 0.1kW | ±1%±10 digits |
PF & cosФ | 0 ~ 1 | 0.01 | ±0.1% |
kWh, kVAh, kvarh | depends on nominal voltage and current clamps | ±1%±10 digits | |
Flicker (IEC61000-4-15) | |||
Pst(10min)/Plt (2 hrs) | 0.00 ~ 20.00 | 0.01 | ±5% |
Unbalance | |||
Voltage | 0.0 ~ 20.0% | 0.1% | ±0.1% |
Current | 0.0 ~ 20.0% | 0.1% | ±1% |
Voltage Phase | -360° ~ 0° | 0.1° | ±0.1° |
Current Phase | -360° ~ 0° | 0.1° | ±0.5° |
Voltage Transient | |||
Vpk | ±6000Vpk | 1V | ±15% |
Vrms | 10 ~ 1000Vrms | 1V | ±2.5% |
Min. Test Time | 6.5us | ||
Inrush Current | |||
Arms | depends on current clamps | 0.01 | ±1% ± 5digits |
Inrush Duration | 1 ~ 32min selectable | 10ms | ±20ms |
Logger | |||
Recording | user-defined parameters for 4 phases at the same time | ||
Memory | Data stored in TF card, 32GB | ||
Duration Time | 2 hrs to 1 year, depends on the recording items and time interval | ||
Interval | 1s to 60 minutes |
CT clamps: (Option)
A: Range: 5A, Output Voltage Ratio: 10mV/A Accuracy: 0.2%
Working Frequency: 45Hz~55Hz Clamps Radius: 8mm
Size: 158*43*24mm
B: Range: 50A, Output Voltage Ratio: 10mV/A Accuracy: 0.2%
Working Frequency: 50Hz~400Hz Clamps Radius: 8mm
Size: 171*46*27mm
C: Range: 100A, Output Voltage Ratio: 10mV/A Accuracy: 0.2%
Working Frequency: 50Hz~400Hz Clamps Radius: 13mm
Size: 174*52*27mm
D: Range: 1A~1000A, Output Voltage Ratio: 1mV/A Accuracy: 1%
Working Frequency: 40Hz~100Hz Clamps Radius: 52mm
Size: 111*216*45mm
E: Flex type Primary Current Rating: 3000A , Output Voltage Ratio: 65mV/1000A
Range: 15A~3000A Accuracy: 1%+position Error
Maximum Allowable imput: 100KA Phase Error: Less than 1%
Noise: less than 2mVrms(10Hz~10Khz) Frequency Characteristic: 10Hz~10KHz(-3db)
Weight: 130g Length: 200cm CT perimeter: 50cm Postion Error: 2%
F: Flex type Primary Current Rating: 5000A , Output Voltage Ratio: 50mV/1000A
Range: 20A~1000A Accuracy: 1%+position Error
Maximum Allowable imput: 100KA Phase Error: Less than 1%
Noise: less than 2mVrms(10Hz~10Khz) Frequency Characteristic: 10Hz~10KHz(-3db)
Weight: 130g Length: 200cm CT perimeter: 50cm Postion Error: 2%
General | |
Batteries Inside | Lithium ion, 7.4V 5200mAh |
Characteristic | Dips and swell, Harmonic(IEC61000-4-30), Power and Energy |
Power Quality Analyzer Class A Energy Analyzer Harmonic Tester
- Product Code: PQAN-7620
- Availability: 2-3 Days
-
$3,328.00
Related Products
AC/DC Current Clamp Meter 70mm CT True RMS Leakage Tester
AC/DC Current Clamp Meter 70mm CT True RMS Leakage Tester Bluetooth Wireless Data Transfer Mult..
$193.00
0.000Ω~2000Ω Grounding Grid Earth Resistance Tester
0.000Ω~2000Ω Grounding Grid Earth Resistance Tester Features: Measurement of..
$2,478.00
UT161B UT161E UT161D Smart Digital Multimeter NCV True RMS
UT161B UT161E UT161D Smart Digital Multimeter True RMSUT161 series are reliable true RMS digital mul..
$62.55
Cheap 4-Terminal Earth Ground Resistance and Soil Resistivity Tester
4-Terminal Earth Ground Resistance and Soil Resistivity Tester SpecificationsMaximal ear..
$158.99
UT206A Auto Range 1000A Digital Clamp Meter Temperature Tester
UNI-T UT206A Auto Range 1000A LCD Backlight Digital Clamp Multitester w/ Frequency Duty Cycle Test M..
$78.55
Ground Resistance Clamp Meter 0.01-1200Ω Tong Tester
Ground Resistance Clamp Meter 0.01-1200Ω Tong Tester Feature: 1. Multi‑fu..
$299.75
Flexible Current Clamp Meter Leakage Current Tester 0-10000A
Flexible Current Clamp Meter Leakage Current Tester 0-10000A &nb..
$96.99
UT582 Digital RCD ELCB Tester AUTO RAMP Leakage Electricity Tester
UT582 Digital RCD (ELCB) Tester AUTO RAMP Leakage Electricity Tester &nbs..
$123.00
Tags: Power Quality Analyzer, Energy Analyzer, Harmonic Power Analyzer
Featured
DIN 862 Digital Caliper Extra Large Display Vernier Caliper Slide
DIN 862 Digital Caliper Extra Large Display Vernier Caliper Slide ISO17025 Not Including Th..
$28.99 $35.99
Steel Wire Rope Hoisting Cable Diameter Digital Caliper Sponge Thickness Vernier Caliper
Steel Wire Rope Hoisting Cable Diameter Digital Caliper With Large Measuring Jaw Sponge Th..
$77.99
Universal Bridge Cam Welding Gage
Universal Bridge Cam Welding Gage WGU-8M WG-218 is updated from ROK WG-208, These two ..
$18.99
Dual Range NCV test 35/6 Bit Digital Multimeter
Dual Range NCV test 35/6 Bit Digital Multimeter Features: 1. AC DC measureme..
$48.90
Latest
Three Phase Digital Power Clamp Meter 200mm Coil CT Power Tester
Three Phase Digital Power Clamp Meter 200mm Coil CT Power Tester Features: Measure th..
$220.00
AC 0.0A~2000A Three Phase Power Clamp Meter Tong Tester
AC 0.0A~2000A Three Phase Power Clamp Meter Tong Tester ..
$278.00
100m Laser Distance Meter with Area and Volume Calculation
100m Laser Distance Measurer Wave Length 620~690nm Features: Compact and efficient mea..
$35.88
60m Laser Distance Measurer Wave Length 620~690nm
60m Laser Distance Measurer Wave Length 620~690nm Features: Compact and efficient meas..
$29.88
AC Three Phase Clamp Power Meter Electric Energy 72000kWh
AC Three Phase Clamp Power Meter Electric Energy 72000kWh Reactive Power 720kvar Power Factor 0.3~1...
$455.00
300mm Flexible AC Current Clamp Multimeter 0mA~10000A Clamp on Ammeter
300mm Flexible AC Current Clamp Meter 0mA~10000A Clamp on Ammeter Eletrical Tester CAT III Featur..
$138.00
Flexible Large Current Clamp Meter 0mA~10000A Switching Test
Flexible Large Current Clamp Meter 0mA~10000A Switching Test What's New? Measurem..
$110.00
Digital Tread Depth Gauge With Slim Contact Bar Stainless Steel
Digital Tread Depth Gauge With Slim Contact Bar Features: Stainless steel , Strong for l..
$18.80